VD911 – 11-pin Traffic Detector

The 1pin base format is commonly used on highway and older domestic applications. However the pin connections are not always the DSP11same. The VD911 uses the more common American format.

At the heart of the VD911 is the 907 architecture, tuned for reliability and simple installation. As with the “Dinky”, you get auto tuning and negligible cross-talk from the Diablo HYPERTRACK software.

The VD911 is ‘Presence Only” suitable for safety and access applications only.

 

 

 

 

Diablo Controls has been listening!  We now offer a complete line of simple, switchless, single output vehicle detectors available with the industry standard 11-pin base. This micro-sized detector will automatically adjust its sensitivity level when used on different sized loops. The detector loop inductance should be between 20 and 2000 microhenries.

This series of Diablo Controls detectors are covered by United States Patent number US 7,132,959 “Non-Interfering Vehicle Detection.”

Ordering Information
DSP-11-LV  = Low voltage model (10 to 30 volts AC or DC)
DSP-11-117 = 117 volts AC
DSP-11-230 = 230 volts AC

  • Works on any in-ground inductive loop from 20 to 2000 microhenries
  • Designed to be cross talk free between other loops
  • Automatically compensates for loop and lead-In sizes
  • Switchless, self-adapting to most common installations
  • Plug and play
  • Small profile, perfect for many installations
  • Fail safe operation
  • Wide low-voltage operation
  • The DSP-11-LV is protected from damage if plugged into a higher voltage.  No need to change a fuse or reset a circuit breaker, simply plug the detector into the proper voltage and it works.
  • Separate Power/Fail and Detect LEDs
  • Industry standard 11-pin connector in a small plastic case

VD911 - click to download

Overview:  Detector operates on any voltage from 10 to 30 volts AC or DC and draws about 35 milliamps of current with no vehicle on the loop.  This micro-sized detector will automatically adjust its sensitivity level when used on different sized loops.  The detector loop inductance should be between 20 and 2000 microhenries.

LED Indicators: The green Power LED blinks once per second to indicate the detector is operating and powered.  The red Detect LED will turn on when a vehicle is over the loop detection area.

Loop or Wire Failures:  In the case of a loop circuit failure, the green LED flashes slowly (twice per second) for an open loop circuit failure.  The green LED will flash fast (10 times per second) to indicate a shorted loop circuit.

Fail Safe vs Fail Secure:  A fail safe detector will output “detect” when the loop circuit is failed.  This is always useful on a safety loop.  On the free exit loop this will keep the gate open until the situation is fixed. This is useful in applications where it is important to allow traffic flow to continue.  A fail secure detector will never output “detect” when the loop circuit is failed.  This will keep the gate closed.  This is useful in high-security areas or installations where containment is needed.  The DSP-11 is a fail safe detector. Note: Never use a fail secure detector on a safety loop.

Output Relay Ratings: 1A at 125 VAC general use, 1A at 30 VDC

Power: DSP-11-LV (10 to 30 volts AC or DC), DSP-11-117 (117 volts AC), DSP-11-230 (230 volts AC)

Operating Temperature: -35° F to 165° F (-37° C to 74° C)

Size: Height: 1.4" Width: 1.4" Depth: 2.75" overall

Connector: Standard 11-pin (Amphenol 86CP11)

Pin assignments are:
Pin 1 (black wire) - Power in (See model type)
Pin 2 (white wire) - Power in (See model type)
Pin 5 (yellow wire) - Output relay common
Pin 6 (blue wire) - Output relay N.O. - (closes for detect)
Pin 7 (gray twisted wire) - Loop input
Pin 8 (brown twisted wire) - Loop input
Pin 10 (pink wire*) - Output relay N.C. - (opens for detect)
*This wire is black (with white) on some harnesses.

  • Works on any in-ground inductive loop from 20 to 2000 microhenries
  • Designed to be cross talk free between other loops
  • Automatically compensates for loop and lead-In sizes
  • Switchless, self-adapting to most common installations
  • Plug and play
  • Small profile, perfect for many installations
  • Fail safe operation
  • Wide low-voltage operation
  • The DSP-11-LV is protected from damage if plugged into a higher voltage.  No need to change a fuse or reset a circuit breaker, simply plug the detector into the proper voltage and it works.
  • Separate Power/Fail and Detect LEDs
  • Industry standard 11-pin connector in a small plastic case

{No Information Available}

11-Pin Detector Detector Terminals Additional Information Diablo Equivalent
Pin-1 Pin-2 Pin-3 Pin-4 Pin-5 Pin-6 Pin-7 Pin-8 Pin-9 Pin-10 Pin-11
LD400

Procon

Live Neutral Relay 1 Relay 1 Relay 2 Relay 2 Relay 3 Relay 3 Earth Relay 4 Relay 4 Relay output states set VD911 Version 1.X
230vAC

or 12v AC/DC

GND N/C or NO COM N/C or NO COM N/C or NO COM EARTH N/C or NO COM
FT0041

Nortech

Live Neutral Relay 1 Relay 1 Relay 2 Relay 2 Loop Loop Earth Pres Pulse Relay None VD911 Version 1.X
230v DC GND N/O COM N/O COM Loop Loop EARTH NC NC
PD134

Nortech

Live Neutral Relay 1 Relay 1 Relay 2 Relay 2 Loop Loop Earth Relay 1 Relay 2 None VD911 Version 1.X
12/24v DC GND COM N/O COM N/O Loop Loop EARTH NC NC
ULD913

Sensable

Live Neutral Relay 1 Relay 1 Relay 2 Relay 2 Loop Loop Earth Relay 1 Relay 2 None VD911 Version 1.X
12/24v DC GND N/O COM N/O COM Loop Loop EARTH NC NC
FLUX11

Centurion

Live Neutral Relay 1 Relay 1 Relay 2 Relay 2 Loop Loop Earth Relay 1 Relay 2 None VD911 Version 1.X
12/24v DC GND N/O N/C N/O N/C Loop Loop EARTH COM COM
LDP1/24

Nortech

Earth Neutral Relay 1 Relay 1 Relay 2 Relay 2 Loop Loop Live Relay 1 Relay 2 None VD911 Version 1.X
EARTH GND N/O N/C N/O COM Loop Loop 12/24 vDC COM N/C